For this reason, Beer's Law can only be applied when there is a linear relationship. Do you have any questions or requests? Use this form to contact our specialists. About Products. Related products. First name. There are also several variations of the spectrophotometry such as atomic absorption spectrophotometry and atomic emission spectrophotometry.

A spectrophotometer is an instrument that measures the amount of photons the intensity of light absorbed after it passes through sample solution. With the spectrophotometer, the amount of a known chemical substance concentrations can also be determined by measuring the intensity of light detected.

Depending on the range of wavelength of light source, it can be classified into two different types:. In visible spectrophotometry, the absorption or the transmission of a certain substance can be determined by the observed color. For instance, a solution sample that absorbs light over all visible ranges i.

On the other hand, if all visible wavelengths are transmitted i. Visible spectrophotometers, in practice, use a prism to narrow down a certain range of wavelength to filter out other wavelengths so that the particular beam of light is passed through a solution sample.

Figure 1 illustrates the basic structure of spectrophotometers. It consists of a light source, a collimator, a monochromator, a wavelength selector, a cuvette for sample solution, a photoelectric detector, and a digital display or a meter. Detailed mechanism is described below. Figure 2 shows a sample spectrophotometer Model: Spectronic 20D. A spectrophotometer, in general, consists of two devices; a spectrometer and a photometer.

A spectrometer is a device that produces, typically disperses and measures light. A photometer indicates the photoelectric detector that measures the intensity of light. You need a spectrometer to produce a variety of wavelengths because different compounds absorb best at different wavelengths. For example, p-nitrophenol acid form has the maximum absorbance at approximately nm and p-nitrophenolate basic form absorb best at nm, as shown in Figure 3. Looking at the graph that measures absorbance and wavelength, an isosbestic point can also be observed.

An isosbestic point is the wavelength in which the absorbance of two or more species are the same. The PMT amplifies the signal from the transmitted light and results in a voltage indicative of its intensity. In order to scan absorbance over a range of wavelengths, PMT-based systems use a monochromator that selects the desired wavelength for each point in the spectrum and measures them sequentially. This is the main difference to the second type of absorbance detectors, the spectrometer.

It splits the transmitted light into different wavelengths and these are directed onto a CCD detector, capturing the intensity of all wavelengths at once. This way, spectra as well as single or few wavelengths measurements can be acquired in a similar amount of time. Otherwise the absorbance measurement will result in maximum absorbance in all samples. Comparing cuvette with microplate measurements. The path length in cuvettes is normalized to 1 cm but in microplates it changes dependent on volume and plate format.

Therefore, absorbance acquired in microplates is typically lower than the absorbance of the same solution measured in cuvettes. If aqueous solutions are measured the microplate measurement can be normalized to 1 cm by using the water-peak path length correction.

Determination of the path length further allows to calculate analyte concentrations with Beer-Lambert law. For measurements in a microplate is recommended to always use the same volume to generate the same path length for all samples. However, in samples with a meniscus, the path length may be different despite of using the same volume.

Again, for aqueous solutions the water-peak path length correction can be used to overcome the problem or to determine the path length for Beer-Lambert calculations. Anything which is in the light path will increase the measured absorbance. Often these are air bubbles in the sample, condensation on a lid, dust, scratches or fingerprints on the bottom of the plate. Hence, checking the plate just before measurement is recommended.

Many absorbance measurements aim at determining the concentration of proteins in solution. Several colorimetric methods are available to measure whole protein content of a sample. This is required to normalize protein samples before downstream applications such as western blots or immunoprecipitations. Using absorbance, it is as well possible to quantify a specific protein in solution.

In brief, an antibody immobilized in the microplate well binds specifically to the protein of interest and captures it in the plate. A second antibody that is likewise specific for the protein of interest binds to the captured protein and can be recognized by secondary enzyme-bearing antibody. Accordingly, the more protein of interest is present in the sample, the more enzyme will be bound in the microplate well. A substrate converted by the enzyme to a chromophore can finally be measured by absorbance and report on the amount of the specific protein present in the sample 3.

Colorimetric assays that report on cell health are popular as they are quick and cost effective. When employing a microplate many conditions can be tested at once. Absorbance-based methods mainly rely on the capability of metabolically active cells to reduce substrates such as MTT or Resazurin. Their reduced forms display absorbance at specific wavelengths and thus report on the metabolic activity of a cell sample, a characteristic often affected by cell viability 4.

Our cell viability blog post describes in detail colorimetric and other methods to measure cell health. The particles bacteria or yeast in microbial suspensions scatter light: the more microbes are present in solution, the more light is scattered. This also means less light reaches the detector and the measured transmission is lower.

In this way, higher absorption is calculated for increased numbers of microbes, although this change is caused solely by an increase in light scattering instead of specific absorbance at nm. Read why the method is used so intensively, how it developed and what should be considered in the OD measurement. Figure 2: The connection between transmission and absorbance of light:. The Lambert-Beer law, which forms the physical basis for photometric applications, describes that the absorption of light by a sample is directly proportional to its concentration and its path length.

Altogether, three parameters contribute to the absorbance value of a sample: first, the concentration C of the molecule; second, the path length L of the sample, which generally equals the path length of the cuvette. The extinction coefficient is a physical constant unique to the molecule; it describes its property of absorbing light at a specific wavelength. This material-specific constant is known for a number of substances, including nucleic acids and various proteins, and the values have been published in the pertinent literature.

In these cases, concentration can be determined instantly. If the value is not known, however, it is possible to enlist the help of a calibration curve.

In order to generate a calibration curve, standards are required, i. These are measured in the photometer prior to the actual sample.